fbpx

Designing Suspended Ceilings
for Seismic Resilience

When it comes to designing suspended ceilings to withstand seismic loads, there are a number of solutions to consider.

When it comes to designing suspended ceilings that can withstand seismic forces, there are several solutions available. Choosing the most suitable approach largely depends on the specifics of each project. Here are some critical factors to consider when implementing seismic bracing solutions:

  • Differential Movement: Understanding how the ceiling interacts with the building structure during seismic events.
  • Weight Considerations: The weight of the ceiling influences the magnitude of seismic loads it must endure.
  • Horizontal Load Resistance: Ensuring the system can effectively handle horizontal seismic forces.
  • Load Transfer Mechanisms: Safely transferring these loads back to the building structure through appropriate bracing.

There are three common methods used to seismically brace suspended ceilings:

Figure 1: Typical Fixed Edge Installation

1.0 Fix – Float

The first and simplest method is to ‘Fix’ and ‘Float’ the ceiling. This means mechanically fixing two adjacent edges of the ceiling to the surrounding walls and leaving the two opposite ceiling edges free to move horizontally. The fixed edge transfers the ceiling’s seismic loads into the surrounding walls which are fixed back to the building structure as shown in Figure 1 (above). The floating edge allows for the differential movement between the ceiling and the walls/structure and is typically achieved through the use of a seismic clip such as the Rondo XD17 clip (ACM7) as shown in Figure 2 (below).

Figure 2: Typical Floating Edge Installation

The Fix – Float method is the quickest and easiest method to install as minimal additional materials are required, perimeter connections and seismic clips are all that is needed.

Unfortunately, this bracing method can only be used for small or lightweight ceilings as the seismic load increases with the overall ceiling weight causing the perimeter connections to become overloaded above a certain ceiling area.

2.0 Seismic Gap

When the ceiling can no longer be fixed and floated because the perimeter connections are overloaded, the next bracing option is to use seismic gaps. Seismic gaps split the ceiling into smaller areas which can then be fixed and floated. The seismic gap itself will act as the floating edge allowing for differential movement and the opposing perimeter edges of the ceiling needs to be fixed to transfer the seismic loads back to the structure.

Seismic gaps in tile and grid ceilings can be easily achieved with the use of seismic clips including the Rondo XD35 clip (DH4) as shown in Figure 3 (see below).

Figure 3: Typical Tile Ceiling Seismic Gap

Seismic gaps in solid (typically plasterboard) ceilings can be a little more difficult as both the lining and ceiling grid must be cut to ensure enough movement is achieved. The break in the lining affects the aesthetic of the ceiling, which is not always desirable. For standard plasterboard ceilings, it can be hidden through the use of a plasterboard control joint.

The seismic gap method is again limited by the perimeter connection capacity, although the size/weight of the ceiling that can be braced in this way is up to 4x greater than the fix-float method.

3.0 Back Bracing

When perimeter fixing bracing methods are not an option, the ceiling must then be braced to the structure above. This is typically done through steel stud bracing and the Tracklok Gridlok range as shown in Figure 4 (see below).

Figure 4: Typical Back Brace

As the suspended ceiling is now rigidly braced to the floor above, it is essential that floating perimeter connections are installed on all surrounding walls to allow for differential movement, ensuring no damage in an earthquake. The size of the seismic gap is dependent on the height of the plenum (distance between the suspended ceiling to the structure above) as well as the inter-story drift of the building.

This bracing method is a lot more labour/material intensive due to the additional braces and the time associated with installing them. The advantage of this method is that essentially all ceilings, no matter the size or weight, can be braced in this way. One difficulty that can arise using this method is when there are a significant amount of services in the plenum space, which highlights the importance of considering seismic design as early as possible in the design process.

At Potter Interior Systems, we can offer the most practical and compliant solutions for your projects. If you have any questions about seismic design and ceiling bracing solutions, we welcome you to get in touch with us. We offer to facilitate seismic and PS1 designs with our engaged engineers for architects to implement compliance during the early design phases of a project to eliminate risk, and now with the increasing demand of councils requiring at consent stage.

© Potter Interior Systems 2024

Cart Item Removed. Undo
  • No products in the cart.